Digital Mammography DM-110MA (Analog)

Mammography System
•Rating power: 5000VA
•Integrated System (Generator Integrated within the main device)
•High voltage generator output: ≥100 kHz, 20 kV to 40 kV increment step: 1 kV
•High performance X-ray tube: Standard:Molybdenum Anode, Focal Spot Size: 0.1
mm (Small)/ 0.3 mm (Large) Optional:Tungsten Anode, Focal Spot Size: 0.1 mm
(Small)/ 0.3 mm (Large)
•Support isocenter rotation function
•C-arm Rotation range: +180° ~ -135°
•Height range of breast support surface: 735mm-1315mm
•C-arm power-driven electrically, Dual side digital display
•Compression plate: flexible and multi-level smart Compression
•Spatial Resolution: >6 Lp/mm
•Detector type: Amorphous Silicon Detector
•Effective Imaging Area: 24×30cm
•Acquisition Station compatible with DICOM 3.0
•Focal distance : 650mm
•Added filter: Mo / Rh
•Added filter Switch: Manual/Automatic
•X-ray Field adjustment: Manual
•Magnification factor: 1.5
•Exposure mode: Manual / AEC
•Supply: 220V~,±10%
•Frequency: 50/60Hz±1Hz
•Max. power : 5000 VA
•N.W.: 240 Kg
•Compact design, minimum device height: < 1.1 m

•Packing Size: 121×94×145 CM

High-Voltage Generator
•Frequency:≥100KHz
•Tube voltage Range: 20 kV ~ 40 kV in 1 kV step
•Max Output: 4 kW
•Max tube voltage: 40kV
•Max tube current: 140mA
•Max current time product: ≥630mAs
•Ripple: <4%
X-Ray Tube
Standard
•Imported X-ray tube for Mammography
•Anode Type: Molybdenum
•Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)
•Permanent filtration: 0.5mmBe
•Max anode speed: 10000rpm/min
•Max tube voltage:40kV
•Max tube current: 35mA(small)/140mA(Large)
•Anode heating capacity: 300 kHu
Optional
•Imported X-ray tube for Mammography
•Anode Type: Tungsten
•Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)
•Permanent filtration:0.5mmBe
•Max anode speed: 10000rpm/min
•Max tube voltage:49kV
•Max tube current: 35mA(small)/140mA(Large)
•Anode heating capacity: 300 kHu

Description

Mammography System
•Rating power: 5000VA
•Integrated System (Generator Integrated within the main device)
•High voltage generator output: ≥100 kHz, 20 kV to 40 kV increment step: 1 kV
•High performance X-ray tube: Standard:Molybdenum Anode, Focal Spot Size: 0.1
mm (Small)/ 0.3 mm (Large) Optional:Tungsten Anode, Focal Spot Size: 0.1 mm
(Small)/ 0.3 mm (Large)
•Support isocenter rotation function
•C-arm Rotation range: +180° ~ -135°
•Height range of breast support surface: 735mm-1315mm
•C-arm power-driven electrically, Dual side digital display
•Compression plate: flexible and multi-level smart Compression
•Spatial Resolution: >6 Lp/mm
•Detector type: Amorphous Silicon Detector
•Effective Imaging Area: 24×30cm
•Acquisition Station compatible with DICOM 3.0
•Focal distance : 650mm
•Added filter: Mo / Rh
•Added filter Switch: Manual/Automatic
•X-ray Field adjustment: Manual
•Magnification factor: 1.5
•Exposure mode: Manual / AEC
•Supply: 220V~,±10%
•Frequency: 50/60Hz±1Hz
•Max. power : 5000 VA
•N.W.: 240 Kg
•Compact design, minimum device height: < 1.1 m

•Packing Size: 121×94×145 CM

High-Voltage Generator
•Frequency:≥100KHz
•Tube voltage Range: 20 kV ~ 40 kV in 1 kV step
•Max Output: 4 kW
•Max tube voltage: 40kV
•Max tube current: 140mA
•Max current time product: ≥630mAs
•Ripple: <4%
X-Ray Tube
Standard
•Imported X-ray tube for Mammography
•Anode Type: Molybdenum
•Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)
•Permanent filtration: 0.5mmBe
•Max anode speed: 10000rpm/min
•Max tube voltage:40kV
•Max tube current: 35mA(small)/140mA(Large)
•Anode heating capacity: 300 kHu
Optional
•Imported X-ray tube for Mammography
•Anode Type: Tungsten
•Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)
•Permanent filtration:0.5mmBe
•Max anode speed: 10000rpm/min
•Max tube voltage:49kV
•Max tube current: 35mA(small)/140mA(Large)
•Anode heating capacity: 300 kHu