Description
Medical hospital High Frequency Mobile Digital Radiology Equipment X-ray
Configurations
No. | Product Name | Quantity |
1 | Flat Panel Detector | 1 |
2 | DX Ray Diagnostic Workstation | 1 |
3 | High Frequency Generator | 1 |
4 | X-Ray Tube | 1 |
5 | Collimator | 1 |
6 | Mobile Stand | 1 |
7 | Battery Power Unit | 2 |
8 | Tablet | 1 |
Flat Panel Detector
Specifications
• Model: FN-101C
• Brand: foinoe
• Detector technology: Wireless a-Si Flat Panel Detector
• Scintillator material: CsI
• Images size: 350mm x 430mm
• Static pixel matrix: 2500 x 3052pixels
• Effective pixels: 7.60million
• Pixel size: 140μm
• Spatial resolution: 3.5lp/mm
• Output grayscale: 16bit
• Acquisition time: ≤7s
High Frequency Generator
Specifications
• Model: FN-5-3M
• Brand: FOINOE
• Nominal output power: 32kW
• Max output power: 40kW
• Frequency: 50kHz/60kHz±1Hz
• kV range: 40~150kV, 1kV step
• mA range: 50-400mA
• mAs range: 1~630mAs
• Input power: 220V
X-ray tube
Specifications
• Model: MXZ1301
• Brand: FOINOE
• Focus: 0.6/1.2mm
• Voltage: 150kV
• Anode type: Rotating
• Anode heat capacity: 300kHU
• Anode angle: 12°
Mobile Stand
Specifications
• Model: FN-326-V
• Brand: FOINOE
• The Vertical Movement Range of X-ray Tube Center along the Column: 580~1800mm
• The Telescopic Movement Range of X-ray Tube Center along the Column Side:
720~1220mm
• Stand Column Horizontal Rotation Range: ±315°
• Collimator Rotation Range along the vertical axis: ±90°
• Mobile Stand Size: 1230 × 580 × 1820 mm
Collimator
Specifications
• Brand: FOINOE
• Model: FN-1
• Control: Manual
• Filter: 1.2mm Al
• Light: LED lamp
DX Ray Diagnostic Workstation
Specifications
• Brand: FOINOE
• Model: FN-5
• Display size: 19inch
• Pixel matrix: 1280 x 1024pixels
• Patient Management: manual registration, WORKLIST automatic query.
• Image Acquisition: automatic window adjustment, automatic cropping, automatic transmission.
• Image Processing: image correction, image flipping.
• Image Observation: window width window level adjustment, image flipping, image rotation, image scaling, and restoration.
• Medical Record Report: automatic loading of patient information
• Film Printing: support DICOM3.0 standard laser camera printing.
• DICOM Transfer: send images to any PACS and workstation that complies with the DICOM 3.0 standard.
Other features
Dose control mode
• APR (Anatomically Programmed Radiography) mode
• Manually setting the exposure mode
Mobility performance
• Electrically assisted drive and has brake equipment
• Support switch to manual mode without power
• Slope assist system, maximum movement slope: ≤8 °
Collision resistance
• Collimator protector against human collision
• Braking function for moving object collision
• Slope assist system, maximum movement slope: ≤8 °
Interactive system
• Time-lapse exposure function
• Remote visual observation system and intercom system
Power management system
• Battery power display device
• Independent control system for power assist and high frequency generator exposure output
• Quick charging mode
• Power intelligent management system: computer sleep, high frequency generator sleep mode
• Intelligent power switching function: support exposure during charging
Reviews